{"apiVersion":"v1","directorySlug":"wiregaugecalc-mcp-4afcd20dae","title":"WireGaugeCalc: NEC electrical calculators for the job, free","description":"Wire size, voltage drop, conduit fill, box fill, and ampacity calculators built for electricians. Enter your values, read a code-cited answer, work offline. Free, no signup.","pageUrl":"https://www.mcpbundles.com/skills/wiregaugecalc-mcp-4afcd20dae","connectPath":"importable","connectAction":"import_server","catalogListing":false,"bundleSlug":null,"listingKind":"remote_mcp","kind":"provider","transportUrl":"https://mcp.wiregaugecalc.com/mcp","hostedMcpUrl":null,"toolCount":6,"toolInventoryStatus":"observed","refreshedAt":"2026-11-16T11:41:43.887283+00:00","registryName":"com.wiregaugecalc/wiregaugecalc-mcp-4afcd20dae","registryVersion":"2026.11.16","registryEligible":true,"tools":[{"name":"size_wire","description":"Find the smallest copper or aluminum wire that carries a load, from NEC Table 310.16, and optionally keep the voltage drop of a run under a limit. Use it when the user asks what wire size, gauge or AWG to use for a number of amps, a breaker, a circuit or a run. It needs the load in amps. Ask the user for it and never guess it. Copper, 75 C terminals and no run are used when not given, and every default is listed in `assumptions`: tell the user what was assumed. To also check voltage drop, give b","inputSchema":{"type":"object","required":["load_amps"],"properties":{"system":{"enum":["single_phase","three_phase"],"type":"string"},"voltage":{"type":"number","maximum":1000,"minimum":1},"material":{"enum":["copper","aluminum"],"type":"string"},"load_amps":{"type":"number","maximum":1000,"minimum":0.1},"max_drop_percent":{"type":"number","maximum":10,"minimum":0.5},"one_way_length_ft":{"type":"number","maximum":5000,"minimum":1},"termination_temp_c":{"enum":[60,75,90],"type":"integer","maximum":90,"minimum":60}},"additionalProperties":false},"title":"Size a wire for a load","annotations":{"readOnlyHint":true,"untrustedContentHint":true},"logicalName":"size_wire","displayName":"Size a wire for a load"},{"name":"calculate_voltage_drop","description":"Calculate the voltage drop of a copper or aluminum circuit run: volts lost, percent of the supply, the voltage at the far end, and whether it is within a limit (3 percent by default). Use it when the user asks about voltage drop for a wire of a known size, a length and a load, for example \"voltage drop of 100 ft of 8 AWG at 40 amps on 240 volts\". It needs the wire size, the load in amps, the one-way length in feet and the supply voltage. Ask the user for what is missing and never guess it. Coppe","inputSchema":{"type":"object","required":["wire_size","load_amps","one_way_length_ft","voltage"],"properties":{"system":{"enum":["single_phase","three_phase"],"type":"string"},"voltage":{"type":"number","maximum":1000,"minimum":1},"material":{"enum":["copper","aluminum"],"type":"string"},"load_amps":{"type":"number","maximum":1000,"minimum":0.1},"wire_size":{"enum":["14","12","10","8","6","4","3","2","1","1/0","2/0","3/0","4/0","250","300","350","400","500"],"type":"string"},"max_drop_percent":{"type":"number","maximum":10,"minimum":0.5},"one_way_length_ft":{"type":"number","maximum":5000,"minimum":1}},"additionalProperties":false},"title":"Calculate voltage drop of a run","annotations":{"readOnlyHint":true,"untrustedContentHint":true},"logicalName":"calculate_voltage_drop","displayName":"Calculate voltage drop of a run"},{"name":"get_ampacity","description":"Look up how many amps a copper or aluminum wire of a given size can carry, from NEC Table 310.16, at the 60, 75 or 90 C column. Use it when the user asks \"how many amps can 10 gauge carry\", \"what is the ampacity of 2/0 aluminum\", or wants to check a wire that is already installed. It needs the wire size. Ask the user for it and never guess it. Copper and the 75 C column are used when not given, and listed in `assumptions`. Returns the amps, the small-conductor breaker limit for 14, 12 and 10 AWG","inputSchema":{"type":"object","required":["wire_size"],"properties":{"material":{"enum":["copper","aluminum"],"type":"string"},"load_amps":{"type":"number","maximum":1000,"minimum":0.1},"wire_size":{"enum":["14","12","10","8","6","4","3","2","1","1/0","2/0","3/0","4/0","250","300","350","400","500"],"type":"string"},"termination_temp_c":{"enum":[60,75,90],"type":"integer","maximum":90,"minimum":60}},"additionalProperties":false},"title":"Look up the ampacity of a wire","annotations":{"readOnlyHint":true,"untrustedContentHint":true},"logicalName":"get_ampacity","displayName":"Look up the ampacity of a wire"},{"name":"check_conduit_fill","description":"Check how full a conduit is with THHN or THWN conductors of one size, against the NEC fill limit (53 percent for 1 conductor, 31 percent for 2, 40 percent for more), or find the smallest trade size that passes. Use it when the user asks \"what size conduit for 3 #12 wires\", \"does 6 #10 THHN fit in 3/4 EMT\" or how many wires fit in a conduit. It needs the conductor size and the number of conductors. Ask the user for them and never guess. Without `trade_size` it finds the smallest trade size that p","inputSchema":{"type":"object","required":["conductor_size","conductor_count"],"properties":{"trade_size":{"enum":["1/2","3/4","1","1-1/4","1-1/2","2","2-1/2","3","3-1/2","4"],"type":"string"},"conduit_type":{"enum":["emt","pvc_schedule_40","rmc"],"type":"string"},"conductor_size":{"enum":["14","12","10","8","6","4","3","2","1","1/0","2/0","3/0","4/0","250","300","350","400","500"],"type":"string"},"conductor_count":{"type":"integer","maximum":400,"minimum":1}},"additionalProperties":false},"title":"Check conduit fill","annotations":{"readOnlyHint":true,"untrustedContentHint":true},"logicalName":"check_conduit_fill","displayName":"Check conduit fill"},{"name":"calculate_box_fill","description":"Work out the minimum volume in cubic inches an electrical box needs for its conductors, devices and ground wires, from NEC 314.16(B), and optionally check it against the box volume stamped on the box. Use it when the user asks \"how big a box for 6 #12 wires and a receptacle\" or \"is this 18 cubic inch box big enough\". It needs the wire size (14 to 6 AWG), the number of conductors and the number of devices (switches or receptacles). Ask the user for them and never guess. Ground wires default to pr","inputSchema":{"type":"object","required":["conductor_size","conductor_count","device_count"],"properties":{"device_count":{"type":"integer","maximum":20,"minimum":0},"conductor_size":{"enum":["14","12","10","8","6"],"type":"string"},"box_volume_cuin":{"type":"number","maximum":500,"minimum":1},"conductor_count":{"type":"integer","maximum":60,"minimum":1},"has_cable_clamps":{"type":"boolean"},"has_ground_wires":{"type":"boolean"}},"additionalProperties":false},"title":"Calculate box fill","annotations":{"readOnlyHint":true,"untrustedContentHint":true},"logicalName":"calculate_box_fill","displayName":"Calculate box fill"},{"name":"solve_ohms_law","description":"Solve Ohm's law and power: give any two of volts, amps and ohms and get the third, plus the power in watts (V = I x R, P = V x I). Use it when the user asks for the current, voltage or resistance of a circuit, or the watts of a load, for example \"what is the current at 120 volts across 24 ohms\" or \"what resistance draws 10 amps at 120 volts\". It needs exactly two of the three values. Ask the user for the missing ones and never guess. If the user has watts and volts, divide to get amps first. Ret","inputSchema":{"type":"object","required":[],"properties":{"amps":{"type":"number","maximum":100000,"minimum":0.0001},"ohms":{"type":"number","maximum":1000000000,"minimum":0.0001},"volts":{"type":"number","maximum":1000000,"minimum":0.001}},"additionalProperties":false},"title":"Solve Ohm's law","annotations":{"readOnlyHint":true,"untrustedContentHint":true},"logicalName":"solve_ohms_law","displayName":"Solve Ohm's law"}],"toolSource":"directory_preview","agentAction":"both","installLinks":[{"id":"cursor","label":"Cursor","href":"cursor://anysphere.cursor-deeplink/mcp/install?name=WireGaugeCalc-NEC-electrical-calculators-for-the-job-free&config=eyJ1cmwiOiAiaHR0cHM6Ly9tY3Aud2lyZWdhdWdlY2FsYy5jb20vbWNwIn0%3D"},{"id":"vscode","label":"VS Code","href":"vscode:mcp/install?%7B%22name%22%3A%22WireGaugeCalc-NEC-electrical-calculators-for-the-job-free%22%2C%22type%22%3A%22http%22%2C%22url%22%3A%22https%3A%2F%2Fmcp.wiregaugecalc.com%2Fmcp%22%7D"},{"id":"vscode-insiders","label":"VS Code Insiders","href":"vscode-insiders:mcp/install?%7B%22name%22%3A%22WireGaugeCalc-NEC-electrical-calculators-for-the-job-free%22%2C%22type%22%3A%22http%22%2C%22url%22%3A%22https%3A%2F%2Fmcp.wiregaugecalc.com%2Fmcp%22%7D"},{"id":"claude-web","label":"Claude.ai","href":"https://claude.ai/customize/connectors?modal=add-custom-connector&connectorName=WireGaugeCalc%3A+NEC+electrical+calculators+for+the+job%2C+free&connectorUrl=https%3A%2F%2Fmcp.wiregaugecalc.com%2Fmcp"},{"id":"codex","label":"Codex","copyText":"codex mcp add \"WireGaugeCalc-NEC-electrical-calculators-for-the-job-free\" --url \"https://mcp.wiregaugecalc.com/mcp\""},{"id":"chatgpt","label":"ChatGPT","href":"https://www.mcpbundles.com/docs/integrations/chatgpt"}],"catalogUrl":"https://www.mcpbundles.com/api/directory/v1/servers/wiregaugecalc-mcp-4afcd20dae","callUrl":"https://www.mcpbundles.com/api/directory/v1/servers/wiregaugecalc-mcp-4afcd20dae/tools/{tool}","mcpServerUrl":"https://mcp.wiregaugecalc.com/mcp","liveCatalogUrl":"https://www.mcpbundles.com/api/directory/v1/servers/wiregaugecalc-mcp-4afcd20dae?live=1"}